| Model | WMDC60EU1-2D | WMDC120EU1-2D | WMDC180EU1-2D | WMDC240EU1-2D | ||
|---|---|---|---|---|---|---|
| Basic Parameters | Max Output Power | 60kW | 120kW | 180kW | 240kW | |
| Input Voltage | 400VAC±15% | |||||
| Frequency | 50/60Hz | |||||
| AC Input | Rated Input Current | 92A | 184A | 276A | 368A | |
| AC Input Connection | 3P+N+PE | |||||
| Power Factor | ≥0.99 | |||||
| Enter Line | Bottom enter line | |||||
| Output Voltage Range | 200~1000V | 300~1000V | ||||
| DC Output | Constant Power Range | 0~200A | 0~250A | 0~500A | ||
| Single-Connector Output Current | 0~200A | 0~400A | ||||
| Dual-Connectors Output Current | ||||||
| Current Accuracy | ≤±0.5% | |||||
| Efficiency | >95% | |||||
| Interaction | Launching | QR Code, Swipe (Option) | ||||
| Display | 21.5-inch Android touch screen | |||||
| Security | Safety Function | Realize Temperature Testing, Overvoltage Protection, Under Voltage Protection, Overload Protection, Short- circuit Protection, Ground Protection, Over Temperature Protection, Insulation Monitoring, Polar anti- connection Protection, Lightning Protection, Emergency Stop Protection, Leakage Protection | ||||
| IP degrees | IP54 | |||||
| Structure | Surface Strength | IK10(Screen:IK08) | ||||
| Dimensions(W*D*H) | 750*657*1800mm(W*D*H) | 780*657*1800mm(W*D*H) | ||||
| Cooling Method | Fan cooling | |||||
| Environmental | Temperature | -20°C~+55°C | ||||
| Humidity | 5%~95% | |||||
| Altitude | <2000m | |||||
| Standard | Communication | Ethernet, 4G/WIFI(Option) | ||||
| Charging Standard | IEC 61851-1, DIN 70121, ISO15118, IEC 61851-23, IEC 61851-21-2 | |||||
| Protocol Standard | OCPP2.0.1 | |||||